{"product_id":"blue-sea-systems-c-series-elci-main-circuit-breaker-120-240v-ac-50a","title":"Blue Sea Systems C-Series ELCI Main Circuit Breaker - 120\/240V AC 50A","description":"\u003cp\u003e\u003cstrong\u003eC-Series ELCI Main Circuit Breaker - 120\/240V AC 50A\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProvides over current and leakage protection per ABYC E-11 for whole boat shore power protection\u003c\/li\u003e\n\u003cli\u003eMeets UL 1500 external ignition protection requirements\u003c\/li\u003e\n\u003cli\u003eTrips on short circuit, overload, or leakage to ground\u003c\/li\u003e\n\u003cli\u003eFront panel mountinstalled in a power distribution panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAmperage: 50A\u003c\/li\u003e\n\u003cli\u003eActuator Style: Flat Rocker\u003c\/li\u003e\n\u003cli\u003ePoles: 3\u003c\/li\u003e\n\u003cli\u003eIgnition Protected: Yes\u003c\/li\u003e\n\u003cli\u003eMax Voltage: 120VAC per pole\/240VAC per pole\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Type: Magnetic Hydraulic - trip free\u003c\/li\u003e\n\u003cli\u003eInterrupt Capacity: 5000A\u003c\/li\u003e\n\u003cli\u003eMinimum Operating Temperature: -35 degrees C\u003c\/li\u003e\n\u003cli\u003eMax Operating Temperature: 66 degrees C\u003c\/li\u003e\n\u003cli\u003eLeakage Trip Amps: 30mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e \u003c!--- cis2:m2lumZRk ---\u003e\n\u003cp\u003eThe Blue Sea Systems C-Series ELCI Main Circuit Breaker, part number 3104, is designed to provide comprehensive protection for marine shore power systems. Rated at 50 amps, this breaker is suitable for use in 120\/240V AC applications and features a flat rocker actuator for easy operation. It is installed directly onto a power distribution panel, making it a convenient and reliable choice for marine electrical setups.\u003c\/p\u003e \u003cp\u003eThis circuit breaker offers overcurrent and leakage protection in accordance with ABYC E-11 standards, ensuring safety during shore power connection. It is ignition protected per UL 1500 requirements, making it suitable for marine environments where ignition protection is critical. The breaker trips automatically on short circuits, overloads, or ground leakage, with a leakage trip setting of 30mA, enhancing safety by preventing electrical faults from escalating. With a high interrupt capacity of 5000A, it can handle large fault currents safely, providing peace of mind during operation.\u003c\/p\u003e \u003cp\u003eDesigned to operate efficiently in a wide temperature range from -35 degrees C to 66 degrees C, the Blue Sea Systems C-Series ELCI breaker is built for durability and long-term reliability in demanding marine conditions. Its magnetic hydraulic trip mechanism ensures trip-free operation, preventing the breaker from being held closed during a fault. The flat rocker actuator allows for straightforward operation, and the three-pole configuration ensures balanced protection across all phases of the system. This breaker’s robust construction and compliance with safety standards make it an ideal component for marine electrical systems that require both protection and compliance with industry regulations.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eProvides overcurrent and leakage protection per ABYC E-11 standards for boat shore power systems\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eMeets UL 1500 external ignition protection requirements\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eTrips automatically on short circuit, overload, or leakage to ground\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eFront panel mount installed in a power distribution panel\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eMagnetic hydraulic trip mechanism for trip-free operation\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eHigh interrupt capacity of 5000A for handling large fault currents\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eOperates within a temperature range of -35°C to 66°C for durability in marine environments\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eLeakage trip setting of 30mA for enhanced safety\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eThree-pole design ensures balanced circuit protection\u003c\/li\u003e\u003c\/ul\u003e","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":44528885923882,"sku":"85024","price":518.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/2285\/8794\/files\/85024XL.jpg?v=1783048950","url":"https:\/\/atticusgoods.com\/products\/blue-sea-systems-c-series-elci-main-circuit-breaker-120-240v-ac-50a","provider":"Atticus Goods","version":"1.0","type":"link"}