{"product_id":"victron-energy-gx-tank-140-tank-monitoring-system-for-4-20-ma-and-0-10-v-sensors-part-number-bpp920140100","title":"Victron Energy GX Tank 140 Tank Monitoring System for 4-20 mA and 0-10 V Sensors (Part Number: BPP920140100)","description":"\u003cp\u003e\u003cstrong\u003eGX Tank 140 Tank Monitoring for 4-20 MA, 1-10VDC Sensors - Monitors Up to 4 Sensors *Sensor Not Included\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe GX Tank 140 takes readings from up to four tank level sensors. It is an accessory for our range of GX system monitoring products, of which the Cerbo GX is the most commonly used model.\u003c\/p\u003e\u003cp\u003eTank levels can be read out locally in the system, see screenshot, as well remotely through ourVRM Portal.\u003c\/p\u003e\u003cp\u003eThe GX Tank is compatible with current senders (4 to 20 mA) as well as voltage senders (0 to 10 V). The connection to the GX Device is via USB, which is also how the GX Tank is powered: no additional power wires are required.\u003c\/p\u003e\u003cp\u003eTank sender wiring is kept as simple as possible: two of the four inputs provide a 24 V power supply, to power the sender. The other two channels do require an external power supply, and there is power in the terminal together with fused outputs to facilitate that.\u003c\/p\u003e\u003cp\u003eUpper and lower limits are configurable, to allow using senders that provide only part of the scale, for example, 0 to 5 V.\u003c\/p\u003e\u003cp\u003eTo provide a stable reading, the readings are averaged damping. The damping can be configured between 1 and 60 seconds.\u003c\/p\u003e\u003cp\u003eFaulty sensors and wiring issues are detected: an alarm will be raised when values are out of range.\u003c\/p\u003e\u003cp\u003eFor marine applications, the GX Device can transmit these tank levels on the NMEA 2000 network to be picked up by other displays such as an MFD.\u003c\/p\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e \u003c!--- cis2:m2lumZRk ---\u003e\n\u003cp\u003eThe Victron Energy GX Tank 140 provides a reliable solution for monitoring up to four tank levels using 4-20 mA or 0-10 V sensors. Designed as an accessory for the GX series monitoring devices, including the popular Cerbo GX, this system enables both local and remote tank level readings. Local readings are accessible directly through the system interface, while remote access is available via the VRM Portal, allowing for real-time monitoring from anywhere. The GX Tank 140 simplifies sensor wiring by providing two inputs with integrated 24 V power supply lines, reducing installation complexity, while the other two channels accommodate external power sources. This flexible wiring configuration supports a variety of sensor types and scales, with configurable upper and lower limits to suit different measurement ranges, such as 0 to 5 V sensors. The device features averaging damping adjustable between 1 and 60 seconds, ensuring stable and accurate readings even in fluctuating conditions. Fault detection capabilities identify sensor malfunctions or wiring issues, raising alarms for prompt troubleshooting. In marine applications, the GX Tank 140 can transmit tank level data over the NMEA 2000 network, allowing integration with multi-function displays (MFDs) for comprehensive vessel monitoring. Powered via USB from the GX device, no additional power wiring is necessary, simplifying installation and reducing clutter. Its robust design and flexible configuration make the GX Tank 140 an ideal choice for various industrial and marine tank monitoring needs, ensuring precise and reliable level management without sensor inclusion, which allows users to select sensors suited to their specific requirements.\u003c\/p\u003e\u003cp\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eSupports up to four tank level sensors, compatible with 4-20 mA and 0-10 V signals\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eSimple wiring with integrated 24 V power supply for two inputs and external power options for the others\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eConfigurable upper and lower limits to accommodate various sensor scales\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eAdjustable damping for stable readings, ranging from 1 to 60 seconds\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eFault detection for sensors and wiring issues with alarm notifications\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eRemote monitoring via VRM Portal and local display integration\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eNMEA 2000 network communication for marine applications\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003ePowered via USB connection, eliminating the need for extra power wiring\u003c\/li\u003e\u003c\/ul\u003e\u003cul\u003e\u003cli\u003eDesigned as an accessory for GX monitoring systems, including Cerbo GX\u003c\/li\u003e\u003c\/ul\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":44528970661930,"sku":"89922","price":98.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0692\/2285\/8794\/files\/89922XL.jpg?v=1783054463","url":"https:\/\/atticusgoods.com\/products\/victron-energy-gx-tank-140-tank-monitoring-system-for-4-20-ma-and-0-10-v-sensors-part-number-bpp920140100","provider":"Atticus Goods","version":"1.0","type":"link"}